Router công nghiệp CGR2010
CGR2010
CISCO
https://www.cisco.com/c/en/us/products/collateral/routers/2000-series-connected-grid-routers/data_sheet_c78_593509.html
Tình trạng: Còn hàng
Thông số kỹ thuật
Feature |
Specification |
|
Substation hardening compliance |
IEC 61850-3 IEEE1613 |
|
Embedded hardware-based cryptography acceleration (IPSec + SSL) |
Yes |
|
Total onboard Combo Ethernet WAN Ports |
2 |
|
Grid Router WAN Interface Card (GRWIC) slots |
4 |
|
Double-wide capable GRWIC slots (use of a double- wide GRWIC slot will consume two GRWIC slots) |
2 |
|
Memory DDR2 ECC DRAM - default |
1 GB |
|
Rugged compact flash |
slot 0: 256 MB (Default) slot 1: 256 MB (Optional Expansion for storage) |
|
External USB 2.0 flash memory slots (Type A) |
2 |
|
USB Console port (Type B) (up to 115.2 kbps) |
1 |
|
Serial console port |
1 |
|
Serial auxiliary port |
1 |
|
Power supply options |
Two power supply options: - Low-voltage DC power supply (available in late 2010)
- AC or high-voltage DC power supply
Any combination of power supplies can be inserted into the chassis. Dual power supply configurations are load sharing in redundancy mode, although a single power supply is sufficient for supporting power needs for the system. |
|
Power specifications |
||
AC input voltage (Power Supply Unit 1) |
Nominal Range: 100 - 240 VAC Operating Range: 85 -264 VAC AC supply also accepts a DC input with an operating range of 88 - 300 VDC |
|
DC input voltage (Power Supply Unit 2) |
Nominal Range: 24 - 60 VDC Operating Range: 20 - 75 VDC |
|
AC input frequency |
47 to 63 Hz |
|
AC input current range for AC power supply (maximum) |
2 A |
|
AC input surge current |
<50 A |
|
DC input voltage |
24 - 60 VDC, extended 88-300 VDC (on separate power supply) |
|
System power consumption (with no modules) (Watts) |
30 Watts |
|
Grid Router WIC power consumption |
Typical: 4.5 Watts Maximum: 6 Watts |
|
Physical specifications |
||
Dimensions (H x W x D) |
3.5 x 17.25 x 15 in. (88.9 x 438.2 x 381 mm) |
|
Rack height |
2 RU (rack unit) |
|
Rack-mount 19 in. (48.3 cm) EIA |
Included |
|
Wall-mount |
Yes |
|
Weight with 1 power supply (no modules) |
19 lbs (8.6kg) |
|
Typical weight fully configured with 2 power supplies and 4 GRWICs |
25 lbs (11.4 kg) |
|
Airflow |
Convection and conduction cooling (no fans) |
|
Environmental Specifications |
||
Operating Conditions |
||
Operating Temperature |
-40 ºF to 140ºF (-40 to +60ºC) continuous operating temperature range -40 ºF to 185ºF (-40 to +85ºC) type test for 100 hours at 85ºC |
|
Shock/Vib |
30G @11 ms |
|
Altitude |
10,000 ft (3,048 m) Max operating temp is de-rated with increasing altitude per IEEE 1613-2009 |
|
Relative humidity |
5 to 95% non-condensing |
|
Non-operating conditions |
||
Temperature |
-40ºF to 185ºF (-40ºC to 85ºC) |
|
Relative humidity |
5 to 95% non-condensing |
|
Altitude |
16,000 ft (4,876 m) Max operating temp is de-rated with increasing altitude per IEEE 1613a-2008 |
|
Non-Op Free Fall Drop |
4 in. (100 mm) per ENG-339611 |
|
Operating seismic/earthquake |
NEBS GR-63 (5.4.1) |
|
Non-op shock/vib |
40-50G (3.26 m/s minimum) |
|
Regulatory compliance* |
||
Environmental substation compliance |
IEC-61850-3 IEEE1613 |
|
Immunity |
EN61000-6-2 EN61000-4-2 (ESD) EN61000-4-3 (RF) EN61000-4-4 (EFT) EN61000-4-5 (SURGE) EN61000-4-6 (CRF) EN61000-4-11 (VDI) EN 55024, CISPR 24 EN50082-1 |
|
EMC |
47 CFR, Part 15 ICES-003 Class A EN55022 Class A CISPR22 Class A AS/NZS 3548 Class A VCCI V-3 CNS 13438 EN 300-386 |
|
Safety |
USA: UL 60950-1 Canada: CAN/CSA C22.2 No. 60950-1 Europe: EN 60950-1 China: GB 60950-1 Australia/New Zealand: AS/NZS 60950-1 Rest of World: IEC 60950-1 CSA certified to UL/CSA 60950-1, 2nd Ed. CB report to IEC60950-1, 2nd Ed., covering all group differences and national deviations |
|
Telecom |
US: TIA-968-A CA: CS-03 EU: TBR1, 2, 4, 12, 13 RTTE Directive Australia: AS/ASIF S016, S038 Japan: JATE |
|
Telecom interface standards |
T1/E1 GRWIC: ITU-T G.703, G.704, G.706, G.823, ANSI T1.403 8-port Asyn/Sync RS-232 GRWIC: RS232, ITU-T V.11 |